Gas Washer/Dryer
PRODUCT MODEL NUMBER
OVERALL DIMENSIONS
LTG6234D
Gas supply: Dryer is equipped for use with
NATURAL gas. Dryer can be converted to L.P. gas.
When rigid pipe is used it should be 1/2 inch IPS.
When acceptable to the gas supplier and local
codes, 3/8-inch approved tubing may be used for
lengths under 20 feet. For lengths over 20 feet,
larger tubing should be used. This washer/dryer is
equipped with its own permanent, flexible gas
connector, design-certified by CSA International,
for connecting the appliance to the gas supply line.
An individual manual shutoff valve must be
installed within 6 feet of the dryer in accordance
with the National Fuel Gas Code ANSI
71⁵⁄₈"
(181.9 cm)
23³⁄₄"
(60.3 cm)
32¹⁄₄"
(81.9 cm)
* Most installations require a
minimum 5¹⁄₂" (14 cm) clearance
behind the dryer for the exhaust
vent with elbow.
Z223.1/NFPA 54.
Electrical: A 120-volt, 60-Hz., AC-only, 15- or
20-amp, fused electrical supply is required. A
time-delay fuse or circuit breaker is recommended.
It is also recommended that a separate circuit
serving only this appliance be provided.
*32"
(81.3 cm)
27"
(68.6 cm)
Exhaust venting: Exhaust your dryer to the
outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do
not use plastic or metal foil vent. Exhaust outlet
hood must be at least 12 inches from the ground
or any object that may be in the path of the
exhaust. The dryer can be converted to exhaust
out right or left side.
RECESSED AREA AND CLOSET INSTALLATION
Additional clearances might be required for wall, door and floor moldings.
Rear clearance may be 0" when house exhaust system is lined up directly with dryer exhaust.
C
A
B
6"
3"
(7.6 cm)
(15.2 cm)
48 in.2
EXHAUST VENTING
(310 cm2)
Plan installation to use the fewest number of elbows
and turns.
Maximum length of the exhaust system depends
upon the type of vent used, number of elbows and
the type of exhaust hood. The maximum length for
both rigid and flexible vent is shown in the chart.
24 in.2
3"
(7.6 cm)
(155 cm2)
5¹⁄₂"
(14 cm)
27"
1"
1" 32"
1"
(2.5 cm)
B
(68.6cm) (2.5cm) (2.5 cm) (81.3 cm)
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
4"
(10.2 cm)
A
4"
(10.2 cm)
(6.4 cm)
4"
(10.2 cm)
DRAIN SYSTEM
Angled hood style
A. Louvered hood style
Standpipe drain system - wall or floor
B. Box hood style
The standpipe drain requires a minimum diameter standpipe of 2" (5 cm). The minimum carry-away
capacity can be no less than 17 gal. (64 L) per minute. A 2" (5 cm) diameter to 1" (2.5 cm) diameter
standpipe adapter kit is available.
The top of the standpipe must be at least 39" (99 cm) high and no higher than 96" (2.4 m) from the
bottom of the washer.
Laundry tub drain system
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top of the laundry tub must be at least
34" (86.4 cm) above the floor and no higher than 96" (2.4 m) from the bottom of the washer.
Vent Length Chart
No. of
90° turns
or elbows
Type of Vent
Box or
Louvered
hoods
Angled
hoods
0
1
2
Rigid metal
37 ft (11.3 m)
25 ft (7.6 m)
35 ft (10.7 m)
20 ft (6.1 m)
Flexible metal
Rigid metal
Flexible metal
32 ft (9.7 m)
21 ft (6.4 m)
27 ft (8.2 m)
16 ft (4.9 m)
Floor drain system
The floor drain system requires a siphon break that may be purchased separately.
The siphon break must be a minimum of 28" (71 cm) from the bottom of the washer. Additional hoses
might be needed.
Rigid metal
Flexible metal
24 ft (7.3 m)
15 ft (4.6 m)
19 ft (5.8 m)
10 ft (3.0 m)
°
NOTE: Side and bottom exhaust adds a 90 turn inside the
xi
washer/dryer. To determine maximum exhaust length, add one
°
90 turn to the chart.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation