Whirlpool Washer Dryer LTG6234D User Manual

®
Gas Washer/Dryer  
PRODUCT MODEL NUMBER  
OVERALL DIMENSIONS  
LTG6234D  
Gas supply: Dryer is equipped for use with  
NATURAL gas. Dryer can be converted to L.P. gas.  
When rigid pipe is used it should be 1/2 inch IPS.  
When acceptable to the gas supplier and local  
codes, 3/8-inch approved tubing may be used for  
lengths under 20 feet. For lengths over 20 feet,  
larger tubing should be used. This washer/dryer is  
equipped with its own permanent, flexible gas  
connector, design-certified by CSA International,  
for connecting the appliance to the gas supply line.  
An individual manual shutoff valve must be  
installed within 6 feet of the dryer in accordance  
with the National Fuel Gas Code ANSI  
71⁵⁄₈"  
(181.9 cm)  
23³⁄₄"  
(60.3 cm)  
32¹⁄₄"  
(81.9 cm)  
* Most installations require a  
minimum 5¹⁄₂" (14 cm) clearance  
behind the dryer for the exhaust  
vent with elbow.  
Z223.1/NFPA 54.  
Electrical: A 120-volt, 60-Hz., AC-only, 15- or  
20-amp, fused electrical supply is required. A  
time-delay fuse or circuit breaker is recommended.  
It is also recommended that a separate circuit  
serving only this appliance be provided.  
*32"  
(81.3 cm)  
27"  
(68.6 cm)  
Exhaust venting: Exhaust your dryer to the  
outside. Four-inch diameter vent is required. Rigid  
or flexible metal exhaust vent must be used. Do  
not use plastic or metal foil vent. Exhaust outlet  
hood must be at least 12 inches from the ground  
or any object that may be in the path of the  
exhaust. The dryer can be converted to exhaust  
out right or left side.  
RECESSED AREA AND CLOSET INSTALLATION  
Additional clearances might be required for wall, door and floor moldings.  
Rear clearance may be 0" when house exhaust system is lined up directly with dryer exhaust.  
C
A
B
6"  
3"  
(7.6 cm)  
(15.2 cm)  
48 in.2  
EXHAUST VENTING  
(310 cm2)  
Plan installation to use the fewest number of elbows  
and turns.  
Maximum length of the exhaust system depends  
upon the type of vent used, number of elbows and  
the type of exhaust hood. The maximum length for  
both rigid and flexible vent is shown in the chart.  
24 in.2  
3"  
(7.6 cm)  
(155 cm2)  
5¹⁄₂"  
(14 cm)  
27"  
1"  
1" 32"  
1"  
(2.5 cm)  
B
(68.6cm) (2.5cm) (2.5 cm) (81.3 cm)  
A. Recessed area  
B. Side view - closet or confined area  
C. Closet door with vents  
4"  
(10.2 cm)  
A
4"  
(10.2 cm)  
(6.4 cm)  
4"  
(10.2 cm)  
DRAIN SYSTEM  
Angled hood style  
A. Louvered hood style  
Standpipe drain system - wall or floor  
B. Box hood style  
The standpipe drain requires a minimum diameter standpipe of 2" (5 cm). The minimum carry-away  
capacity can be no less than 17 gal. (64 L) per minute. A 2" (5 cm) diameter to 1" (2.5 cm) diameter  
standpipe adapter kit is available.  
The top of the standpipe must be at least 39" (99 cm) high and no higher than 96" (2.4 m) from the  
bottom of the washer.  
Laundry tub drain system  
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top of the laundry tub must be at least  
34" (86.4 cm) above the floor and no higher than 96" (2.4 m) from the bottom of the washer.  
Vent Length Chart  
No. of  
90° turns  
or elbows  
Type of Vent  
Box or  
Louvered  
hoods  
Angled  
hoods  
0
1
2
Rigid metal  
37 ft (11.3 m)  
25 ft (7.6 m)  
35 ft (10.7 m)  
20 ft (6.1 m)  
Flexible metal  
Rigid metal  
Flexible metal  
32 ft (9.7 m)  
21 ft (6.4 m)  
27 ft (8.2 m)  
16 ft (4.9 m)  
Floor drain system  
The floor drain system requires a siphon break that may be purchased separately.  
The siphon break must be a minimum of 28" (71 cm) from the bottom of the washer. Additional hoses  
might be needed.  
Rigid metal  
Flexible metal  
24 ft (7.3 m)  
15 ft (4.6 m)  
19 ft (5.8 m)  
10 ft (3.0 m)  
°
NOTE: Side and bottom exhaust adds a 90 turn inside the  
xi  
washer/dryer. To determine maximum exhaust length, add one  
°
90 turn to the chart.  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. 8572777 Rev. A  
12-12-05  
 

Weed Eater Trimmer 545154699 User Manual
Westinghouse Microwave Oven 42204 User Manual
Whirlpool Ventilation Hood RH2600XL 1 User Manual
White Outdoor Blower 315B User Manual
Whynter Air Conditioner ARC 13PG User Manual
Wolf Appliance Company Ventilation Hood PW542418R User Manual
Yamaha Drums DD 20 User Manual
Yamaha Stereo Amplifier A S1000 User Manual
Zebra Technologies Label Maker 2207A10L010 User Manual
Zenith Flat Panel Television E44W46LCD User Manual