Whirlpool Ice Maker GI15NFLT User Manual

®
Ice Maker  
PRODUCT MODEL NUMBERS  
CABINET OPENING DIMENSIONS  
GI15NDXT  
GI15NFLT  
GI15NFRT  
Electrical: A 115 Volt, 60 Hz., AC only, 15- or  
20-amp electrical supply, properly grounded in  
accordance with the National Electrical Code and  
local codes and ordinances is required.  
It is recommended that a separate circuit, serving  
only your ice maker, be provided. Use a receptacle  
which cannot be turned off by a switch or pull  
chain.  
Water: A cold water supply with water pressure  
of between 30 and 120 psi (207 and 827 kPa) is  
required to operate the ice maker.  
IMPORTANT: Reverse osmosis water filtration  
systems can be used only with ice maker  
installations that have a gravity drain. A reverse  
osmosis system is not recommended for ice  
makers that have a drain pump installed.  
11¹⁄₂ "  
(29.2 cm)  
A
B
34"  
(86.4 cm)  
Min.  
¹⁄₂  
28  
(72.4 cm)  
"
34  
¹⁄₂  
"
(87.6 cm)  
Max.  
9"  
(22.9 cm)  
3¹⁄₂ "  
(8.9 cm)  
24"  
(60.1 cm)  
The pressure of the water supply coming out of a  
reverse osmosis system going to the water inlet  
valve of the ice maker needs to be between 30 and  
120 psi (207 and 827 kPa).  
15"  
(38.1 cm)  
A. Recommended location for electrical  
and plumbing fixtures.  
Drain: Either a gravity-drain system or drain  
pump system (on some models) to carry water to  
an existing drain.  
B. Floor level  
DRAIN REQUIREMENTS  
SIDE VIEW  
REAR VIEW  
Drain lines must have a minimum of 5⁄8"  
(15.88 mm) inside diameter.  
Drain lines must have a 1" drop per 48"  
(2.54 cm drop per 122 cm) of run or 1⁄4" drop  
per 12" (6.35 mm per 30.48 cm) of run and  
must not have low points where water can  
settle.  
A
B
A
B
C
D
The floor drains must be large enough to  
accommodate drainage from all drains.  
1⁷⁄₈"  
The ideal installation has a standpipe with a  
1-1⁄2" (3.81 cm) to 2" (5.08 cm) PVC drain  
reducer installed directly below the outlet of the  
drain tube as shown. You must maintain a  
1" (2.54 cm) air gap between the drain hose and  
the standpipe.  
E
(4.8 cm)  
1" (2.54 cm)  
23"  
(58.4 cm)  
C
D
A. Water supply tube clamp  
B. Vent hose (drain pump models only)  
C. Water supply line  
D. Inlet water tube clamp  
E. Drain hose (drain pump models only)  
2" - 1¹⁄₂"  
(5 cm - 3.8 cm)  
It may be desirable to insulate the drain line  
A. Drain hose  
B. 1" (2.54 cm) air gap  
C. PVC drain reducer  
thoroughly up to the drain inlet.  
D. Center of drain should be 23" (58.4 cm) from front of door,  
with or without the ³⁄₄" (1.91 cm) panel on the door. The  
drain should also be centered from left to right (7⁵⁄₁₆"  
[18.57 cm] from either side of the ice maker).  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. W10136155B  
07-28-08  
 

Weed Eater Trimmer 530085765 User Manual
Weider Home Gym WESY59930 User Manual
Weslo Hot Tub WLHS20702 User Manual
Western Digital Computer Drive World Edition II User Manual
Westinghouse Microwave Oven WMG281SF User Manual
Westinghouse Outdoor Ceiling Fan ETL ES GW ContempraTrio MN08 User Manual
Westinghouse Slow Cooker WST3011ZE 3 User Manual
Xilinx Network Card PCI32 User Manual
Yamaha DVD Player DRX 1 User Manual
Zanussi Clothes Dryer TD534 User Manual